Toll Free: 1.800.277.2439 Tel: 803.739.4360

When every ounce Counts!

View Catalog
  • JB4ES & JB4SS TuffSeal Excitation Trim Junction Box (91779, 88956)

    Stainless steel, NEMA 4X enclosure, Shunt jumpers to disable unused load cell parts, PreVent® breather vent, Conformal coated circuit board Number of cells: 2 to 4 single cells, Expansion port

  • JB4ES & JB4SS TuffSeal Excitation Trim Junction Box (91779, 88956)

    Stainless steel, NEMA 4X enclosure, Shunt jumpers to disable unused load cell parts, PreVent® breather vent, Conformal coated circuit board Number of cells: 2 to 4 single cells, Expansion port

  • JB4EP, JB4EPT, JB4SP and JB4SPT TuffSeal Signal Trim Junction Box (89894, 91781, 92763, 89894, 91780, 92762)

    Fiberglass Reinforced Polyester (FRP) (NEMA 4X) enclosure with stainless steel cover screws, Shunt jumpers to disable unused load cell parts, PreVent® breather vent, Conformal coated circuit board Number of cells: 2 or 4 single cells, Expansion port

  • JB4EP, JB4EPT, JB4SP and JB4SPT TuffSeal Signal Trim Junction Box (89894, 91781, 92763, 89894, 91780, 92762)

    Fiberglass Reinforced Polyester (FRP) (NEMA 4X) enclosure with stainless steel cover screws, Shunt jumpers to disable unused load cell parts, PreVent® breather vent, Conformal coated circuit board Number of cells: 2 or 4 single cells, Expansion port

  • EL204 Signal Trim Junction Box (73428)

    ABS enclosure with molded-in cable fittings for waterproof seal, Premium screw terminals, Dale 3296 25-turn cermet potentiometers, 6-screw attachment to lid, die cut gasket for superior environment protection Number of cells: 2 to 4 single cells

  • El504 Signal Trim Junction Box (21165)

    Stainless Steel, NEMA 4X enclosure, Strain relief cable fittings, Removable connectors for easy wiring Number of cells: 2 to 4 single cells (even number of cells only), Any unused channels require modification

  • JB8SP & JB8SPT TuffSeal Signal Trim Junction Box (91782, 91783)

    Fiberglass Reinforced Polyester (FRP) (NEMA 4X) enclosure with stainless steel cover screws, Shunt jumpers to disable unused load cell part, PreVent® breather vent, Removable load cell connectors, Conformal coated circuit board, Number of cells: 2, 4, 6, or 8 single load cells (even number only), Expansion port

  • JB8SP & JB8SPT TuffSeal Signal Trim Junction Box (91782, 91783)

    Fiberglass Reinforced Polyester (FRP) (NEMA 4X) enclosure with stainless steel cover screws, Shunt jumpers to disable unused load cell parts, PreVent® breather vent, Removable load cell connectors, Conformal coated circuit board, Section and individual cell trim capability, Field replaceable transient protection, (1) coupling, 1/2 NPT cord grip to 3/4" NPT conduit fitting for homerun cable, Number of cells: 2, 4, 6, or 8 single load cells (even number only), Expansion port

  • EL304A Signal Trim Junction Box (21169)

    NEMA 4X Fiberglass-Reinforced Polyester (FRP) enclosure, Strain relief cable fittings, Individual cell signal disconnect switches Number of cells: 2 to 4 single cells (even number of cells only), Expansion port

  • JB1010 Signal/Excitation Trim Box with Transient Protection (36231)

    NEMA 4X Fiberglass-Reinforced Polyester (FRP) enclosure, Load cell transient protection, Signal or excitation trim, Front panel mounting, Strain relief cable fittings Number of cells: 1 through 10 with expansion, Trims odd numbers of cells without modification

  • iQUBE² Digital Diagnostic Junction Box

    Enclosure includes four channel boards with or without power supply, NEMA 4X polyester or stainless steel enclosure, Up to 16 load cells can be used connected, Connection can be up to four separate platforms with a system total, or four separate scales systems, Diagnostic routines for weighing errors and system health. Tests for zero return, linearity, and drift, Onboard status LEDs for communications and visual bi-color indication of cell health, Cell Emulator compensates for load cell failure until a repair can be made, Cal-Match algorithm automatically trims and calibrates the scale in one pass of test weights (stopping over each mount), Standard communication RS-232. Option card slot for Fiber Optic, Ethernet TCP/ IP or Wireless TPC/IP, or RS-485, Four digital I/O per card, for push button operation, control, or remote cell status

  • iQUBE² Digital Diagnostic Junction Box

    Enclosure includes four channel boards with or without power supply, NEMA 4X polyester or stainless steel enclosure, Up to 16 load cells can be used connected, Connection can be up to four separate platforms with a system total, or four separate scales systems, Diagnostic routines for weighing errors and system health. Tests for zero return, linearity, and drift, Onboard status LEDs for communications and visual bi-color indication of cell health, Cell Emulator compensates for load cell failure until a repair can be made, Cal-Match algorithm automatically trims and calibrates the scale in one pass of test weights (stopping over each mount), Standard communication RS-232. Option card slot for Fiber Optic, Ethernet TCP/ IP or Wireless TPC/IP, or RS-485, Four digital I/O per card, for push button operation, control, or remote cell status