Cells |
N/A 4 |
Modules |
N/A 1 |
Capacity |
N/A 150000 lb |
Certificate of Conformance |
N/A 03-096A2 |
Scale Capacity |
N/A Up to 270000 lb |
Concentrated Load Capacity |
N/A 100000 lb |
"r" Factor Rating |
N/A 2.94 |
Scale Height |
N/A 17 in |
Available Standard Width1 | N/A 10 ft11 ft |
Weighbridge Deck |
N/A 3/8 in Tread Plate Decking - Welded to Quad Beam Weighbridge |
Steel Preparation |
N/A Commercial Blast Cleaning SSPC-SP6 |
Paint System |
N/A Cross-Linked Two-Part Epoxy - 2 to 4 mil Primer Base Coat |
Load Cell Cable |
N/A Stainless Steel Sheathed Cable with Clear Polymer Coating |
Analog Junction Box |
N/A NEMA 4X FRP Enclosure(s) and B-TEK 4-Cell Summing Board with GDT Surge Protection |
Digital Junction Box |
N/A NEMA 4X Stainless Steel Enclosure(s) and 8-Cell Terminal Board with GDT Surge Protection |
Surge Protection |
N/A CPR-M analog load cells utilize ground straps and base plate isolation disc Surge protection enhanced by Tripp-Lite Isobar Ultra 4-Outlet line transient protection device |
Industry Standards |
N/A NEMA 4X NEMA 4X FRP |
N/A
|